MMI Parameters Table
Display
Parameter
R/L RESET VALUE
Parameters
501 and
506 are visible in the PAR menu when Application 5 is selected in parameter
P
P
PI P GAIN
PI I GAIN
PID D GAIN
F
PID D FILTER TC
F
PID FEEDBACK
GAIN
F
PID LIMIT
F
PID SCALING
F
PID ERROR
F
PID OUTPUT
F
Parameters
P
901 and
P
908 are visible in the PAR menu when there are corresponding entries in the CUSTOM MENU block.
CUSTOM 1
CUSTOM 2
CUSTOM 3
CUSTOM 4
CUSTOM 5
CUSTOM 6
CUSTOM 7
CUSTOM 8
CONTROL MODE This parameter contains the main method of
NAMEPLATE RPM
M
FLY-CATCH
ENABLE
VF
FLY-CATCH
ENABLE
SV
650G AC Drive
Programming Your Application
Description
The value the output is set to when Reset is TRUE,
when DIN4 (terminal 10) is 24V in Application 4
The PI proportional gain
The PI integral gain
The PID derivative gain
In order to help attenuate high frequency noise on
the derivative term, a first order lag has been
provided. This parameter determines the filter time
constant.
A multiplier applied to the feedback signal of the
PID
Determines the maximum positive and negative
excursion (Limit) of the PID output
This parameter represents an overall scaling factor
which is applied after the PID positive and negative
limit clamps
The result of SETPOINT - FEEDBACK x FEEDBACK
GAIN
The output of the PID function block
Select a parameter to be displayed in the PAR
Menu by entering the Tag Number for the
parameter using DSE (or other suitable
programming tool). Eight parameters can be
entered into the menu. CUSTOM 1 is the first of
the new parameters in the menu, CUSTOM 2 is
the second of the new parameters in the menu,
and so on. These parameters contained in P901 to
P908 will appear at the bottom of the parameter
list for the PAR Menu.
Enter 0 to leave a position in the menu unused.
P
As
901
As
P
901
As
P
901
As
P
901
As
P
901
P
As
901
As
P
901
SET::CTRL Menu
motor control used by the drive
This parameter contains the motor nameplate full-
load rated speed. This is the motor speed in rpm
at base frequency minus full load slip
Enables flycatching in Volts/Hz control mode when
TRUE. Allows the drive to catch a spinning load.
Enables flycatching in Sensorless Vector control
mode when TRUE. Allows the drive to catch a
spinning load.
www.comoso.com
6-4
Range
Default
-100.00 to 100.00%
0.00%
1
P
0.00 to 100.00
0.10
0.00 to 100.00
1.00
0.00 to 100.00
0.00
0.05 to 10.00s
0.05s
-10.00 to 10.00
1.00
0.00 to 300.00%
300.00%
-3.0000 to 3.0000
1.0000
—.xx %
—.xx%
.xx %
.xx %
0 to 1655
0
0 to 1655
0
0 to 1655
0
0 to 1655
0
0 to 1655
0
0 to 1655
0
0 to 1655
0
0 to 1655
0
0=VOLTS/HZ
0
1=SENSORLESS VEC
0.1 to 30000.0 RPM
product
code
dependent
0=FALSE
0
1=TRUE
0=FALSE
0
1=TRUE