Environmental Details

Operating Temperature
HEAVY DUTY
NORMAL DUTY
Storage Temperature
Shipping Temperature
Product Enclosure Rating
Frames C, D, E & F
Frames 1, 2 & 3 IP20 (UL Open Type) suitable for cubicle mount only
Cubicle Rating
Altitude
Humidity
Atmosphere
Climatic Conditions
Vibration
Safety
Overvoltage Category
Pollution Degree
Europe
North America/Canada
650G AC Drive
Operating temperature is defined as the ambient temperature to the immediate
surround of the drive, when the drive and other equipment adjacent to it is operating
at worst case conditions.
0C to 45C (0C to 40C with top cover fitted), derate up to a maximum of 50C
0C to 40C (0C to 35C with top cover fitted), derate up to a maximum of 50C
Output power is derated linearly at 2% per degree centigrade for temperature
exceeding the maximum rating ambient for the drive.
-25C to +55C
-25C to +70C
Wall Mounted
IP40 - top cover surface (Europe)
(top cover must be fitted)
IP20 - remainder of surfaces (Europe)
UL (c-UL) Type 1 (North America/Canada)
Cubicle Mounted
IP20
(without top cover fitted)
UL (c-UL) Open Type (North America/Canada)
Through-panel Mounted
IP20
(without top cover fitted)
UL (c-UL) Open Type (North America/Canada)
Cubicle to provide 15dB attenuation to radiated emissions between 30-100MHz. It
must also require a security tool for opening
If >1000 metres (3300 feet) above sea level, derate Motor Power Rating by 1% per
100 metres (330 feet) to a maximum of 2000m (6561 feet)
Maximum 85% relative humidity at 40C non-condensing
Non flammable, non corrosive and dust free
Class 3k3, as defined by EN50178 (1998)
Test Fc of EN60068-2-6
10Hz<=f<=57Hz sinusoidal 0.075mm amplitude
57Hz<=f<=150Hz sinusoidal 1g
10 sweep cycles per axis on each of three mutually perpendicular axis
Overvoltage Category III (numeral defining an impulse withstand level)
Pollution Degree II (non-conductive pollution, except for temporary condensation)
Pollution Degree III (dirty air rating for through-panel mounted parts)
When fitted inside a cubicle, or when wall-mounted and the top cover is firmly screwed in
position, this product conforms with the Low Voltage Directive 2006/95/EC to show compliance.
Without the top cover fitted, complies with the requirements of UL508C as an open-type drive.
When the top cover is fitted, complies with the requirements of UL508C as Type 1 Enclosed (for
direct wall mounting applications) when specified with Model Number Block 6 (Frame B) or
Modle Number Block 4 (Frame C, D, E, F) designation xx20 or xx21 only.