Site Requirements
For safety, periodically check the resistance value of the antistatic strap. The measurement should be
Caution
between 1 and 10 megohm (Mohm).

Environmental Requirements

Ensure adequate spacing between racks using the information in the following table. Keep all of the
vents clear of obstructions, including dust and foreign conductive material, and away from the exhaust
ports of other equipment.
Cisco SCE 8000 environmental requirements.
Table 4-1
Airflow Intake
Right side
Table 4-2
Specification
Temperature
Cisco SCE8000 GBE Installation and Configuration Guide
4-4
When installing a component, use any available ejector levers or captive installation screws to
properly seat the bus connectors in the backplane or midplane. These devices prevent accidental
removal, provide proper grounding for the system, and help to ensure that bus connectors are
properly seated.
When removing a component, use any available ejector levers or captive installation screws to
release the bus connectors from the backplane or midplane.
Handle carriers by available handles or edges only; avoid touching the printed circuit boards or
connectors.
Place a removed component board-side-up on an antistatic surface or in a static shielding container.
If you plan to return the component to the factory, immediately place it in a static shielding
container.
Avoid contact between the printed circuit boards and clothing. The wrist strap only protects
components from ESD voltages on the body; ESD voltages on clothing can still cause damage.
Never attempt to remove the printed circuit board from the metal carrier.
Table 4-1
Chassis Airflow Requirements
Airflow Exhaust
Left side
Ambient Temperature and Humidity Requirements for the Cisco SCE 8000
lists the chassis airflow requirements, and
Air Filter Option
Not applicable
Acceptable Range
Nominal: 32°F to 104°F (0°C to 40°C)
Storage: -4°F to 149°F (-20°C to 65°C)
Chapter 4 Installing the Cisco SCE 8000 Chassis
Table 4-2
Minimum
Minimum
Horizontal
Clearance (walls)
Separation
6 in (15 cm)
12 in (30.5 cm)
lists the