Environmental Requirements - Cisco 9124 - MDS Fabric Switch User Manual

Fabric switch for hp c-class bladesystem
Hide thumbs Also See for 9124 - Cisco MDS Fabric Switch:
Table of Contents

Advertisement

Environmental requirements

To ensure proper operation, the switch must not be subjected to environmental conditions beyond
those for which it was tested. The ranges specified in Table 16 list the acceptable environment for
both operating and non-operating conditions.
Table 15
Environmental requirements
Condition
Ambient temperature
Humidity
Altitude
Shock
Vibration
Airflow
Supported SFPs
Do not use unsupported SFPs; they can affect switch operability. They may not fit correctlyand may
void your warranty. See Optional hardware kits for a list of supported SFPs.
For a complete list of supported devices, refer to the latest version of the HP StorageWorks SAN
design reference guide:
http://h18000.www1.hp.com/products/storageworks/san/documentation.html
Supported HBAs
For a list of HBAs that have been tested and are known to work with the SAN switches, refer to the
latest version of the HP StorageWorks SAN design reference guide:
http://h18000.www1.hp.com/products/storageworks/san/documentation.htm
Acceptable range during operation
104°F/40 °C at sea level, derated
1 C per 1000 ft above sea level
5% to 90% relative humidity,
non-condensing
0 to 10,000 ft (3 km) above sea
level
40 G, 2mS duration
0.5 G, 10 to 500 Hz
47 cubic ft per minute
Cisco MDS 9124e Fabric Switch for HP c-Class BladeSystem
Acceptable range during non-operation
-40°C to 70°C with maximum rate
of change of 20 C /hr
50% to 80% relative humidity,
non-condensing
0 to 40,000 ft (12 km) above sea
level
140 G, 2mS duration
2.0 G, 5 to 500 Hz
None required
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents