Environmental and System Requirements
Table 1
Color
Orange
Green
Green to orange
1. Enter the show environment temperature mod command to display the temperature of each of four sensors on the CSM.
2. CLI = command-line interface.
RJ-45 Connector
The RJ-45 connector, which is covered by a removable plate, is used to connect a management station
device or a test device. This connector is used by field engineers to perform testing and to obtain dump
information.
Environmental and System Requirements
This section describes the environmental and system requirements.
•
•
Environmental Requirements
Table 2
Table 2
Item
Temperature, ambient operating
Temperature, ambient nonoperating
Humidity (RH), ambient (noncondensing)
operating
Nonoperating relative humidity (noncondensing) 5% to 95%
Catalyst 6500 Series Switch Content Switching Module Installation Note
6
Content Switching Module Status LED (continued)
Description
The module is initializing hardware or communicating with the supervisor
•
engine.
A fault occurred during the initialization sequence.
•
The module has failed to download its Field Programmable Gate Arrays
•
(FPGAs) on power up but continues with the remainder of the initialization
sequence and provides the module online status from the supervisor engine.
•
The module has not received module online status from the supervisor engine.
This problem could be caused by the supervisor engine detecting a failure in
an external loopback test that it issued to the CSM.
•
The module is operational; the supervisor engine has provided module online
status.
•
The module is disabled through the supervisor engine CLI
module disable mod command.
Environmental Requirements, page 6
System Requirements, page 7
lists the environmental requirements for the CSM.
CSM Environmental Requirements
Specification
o
o
o
o
0
to 40
C (32
to 104
F)
o
o
o
o
–40
to 70
C (–40
to 158
10% to 90%
2
using the set
F)
78-15751-01