Step 5: Connecting Power To The G450 - Avaya G450 Installing And Upgrading

Hide thumbs Also See for G450:
Table of Contents

Advertisement

Installing the Avaya G450 Media Gateway
3. Cut this ground wire to the length needed to reach the approved ground. Do not coil this
wire.
Note:
The ground block is provided for use with more than one G450 in the rack. It is
Note:
usually mounted by the customer electrician.
If the ground block is not being used
1. Attach the Supplementary Ground Conductor to an approved ground.
2. Connect the AC power cable to the inlet receptacle on the rear of the chassis.

Step 5: Connecting power to the G450

After you have mounted the G450, installed the PSU(s), installed the media modules, and
attached grounding conductors, you can connect power to the G450. The G450 can be ordered
with either one or two power supply units.
1. Connect the power cable to the power connector on the G450 back panel.
2. Plug the power cable into a mains socket. The G450 is now powered.
The PWR LED on the front panel lights. The CPU LED lights up if the firmware is running.
At least one LED on each media module, except the S8300, lights up initially and then
goes off after about 20 seconds.
3. If you have a second power supply unit, you can connect it to power by repeating steps 1
and 2.
Note:
If two PSUs are installed in the G450, the PWR LED blinks if only one PSU is
Note:
connected to power, and stays on if both PSUs are connected to power.
44 Installation and Upgrades for the Avaya G450 Media Gateway