Typical Adjunct Power Connections End-To-End; Auxiliary Power For An Attendant Console - Avaya G450 Installing And Upgrading

Hide thumbs Also See for G450:
Table of Contents

Advertisement

Typical adjunct power connections end-to-end

Figure 144
shows typical connection locations for adjunct power.
Figure 144: Example Adjunct Power Connections
Figure notes:
1. Typical display telephone
2. Individual power supply (Such as 1151B/
C) (Not used if item 14 is used)
3. 400B2 adapter
4. Information outlet (modular jack)
5. 4-pair D-Inside Wire (DIW) cable
6. Satellite site or adapter location
7. 25-pair D-Inside Wire (DIW) cable
8. Station side of MDF

Auxiliary power for an attendant console

The nonessential functions of an attendant console and its optional 26A1 or 24A1 selector
console derive power from an auxiliary power source. Provide auxiliary power for an attendant
console through this cable so the console remains fully operational during short power outages.
Note:
Only 1 console can derive auxiliary power from the system and through the
Note:
auxiliary cable located in the trunk/auxiliary field.
A console's maximum distance from its auxiliary power source is:
800 ft (244 m) for a 302A1
2
1
3
Typical adjunct power connections end-to-end
13
6
4
5
7
14
9. 100P6A patch cord or jumpers
10. System side of MDF
11. 25-pair cable to digital line
modular jack
12. Equipment room
13. Satellite location
14. Bulk power supply. Install at
satellite location or equipment
room (not both).
12
8
10
9
11
14
cydmapwr EWS 052898
Issue 2 June 2008