Connecting a non-FCC-registered music-on-hold source to a G450

using a KS-23395-L4 coupler

Figure 155: Non-FCC-registered music-on-hold equipment connecting to KS-23395-L4 for
a G450 Media Gateway
Figure notes:
1. G450 Media Gateway
2. MM711 Analog Media Module
3. RJ-45 connection
4. KS-23395-L4 coupler
1. Connect one end of an RJ-45 cable to a port in the MM711 Analog Media Module.
2. Connect the other end of the RJ-45 cable to a KS-23395-L4 coupler.
3. Connect the KS-23395-L4 coupler to the 909A/B universal coupler using a 8-pair modular
cord.
4. Connect the 909A/B universal coupler to the music source using a 8-pair modular cord.
5. Administer the switch for the new equipment.
Note:
For additional installation information, refer to 909A/909B Universal Coupler
Note:
Installation Instructions, which is normally shipped with the 909A/909B Universal
Coupler.