Testing the complete configuration
Testing music-on-hold
Verify music is provided to a held party during any hold interval.
Testing emergency transfer (S8700-series Multi-Connect
only)
Put the configuration in emergency transfer mode and make a call with an emergency transfer
telephone. There can be up to four Emergency Transfer panels on a wall in the telephone
closet, depending on the configuration.
Testing terminating trunk transmission
The terminating trunk transmission test provides extension number access to 3 tone
sequences. These tone sequences can be used for trunk transmission testing from the distant
end of the trunks. To test terminating trunk transmission:
1. Type change system-parameters maintenance and press Enter and go to screen 2.
2. Under TERMINATING TRUNK TRANSMISSION TEST (Extension), type in 3 extension
numbers in the 3 fields provided:
Test Type 100:_______Test Type 102:_______Test Type 105:_______
Test type
Test type
100
84 Installing the Avaya G650 Media Gateway
Test features
5.5 seconds of 1004 Hz tone at 0 dB
Quiet until disconnect. Disconnect is forced after 1 minute