Running Post; Post Diagnostic Levels - Sun Microsystems Netra T4 AC100 Service And System Reference Manual

Hide thumbs Also See for Netra T4 AC100:
Table of Contents

Advertisement

Alternatively, from the shell prompt:
# eeprom diag-switch?=true
# eeprom diag-out-console=true
3. Set the diag-level configuration variable to max or min (see Section 2.4, "POST
Diagnostic Levels" on page 2-4).
ok setenv diag-level value
or
# eeprom diag-level= value
Note – The default value is min.
2.3

Running POST

To run POST:
Initiate POST using one of the following methods:
a. Briefly press the power ON/STBY switch to power cycle the system.
b. At the LOM prompt, type
2.4

POST Diagnostic Levels

Two levels of POST are available: maximum (max) level and minimum (min) level.
The system initiates the selected level of POST based on the setting of diag-level,
a configuration variable.
2-4
Netra T4 AC100/DC100 Service and System Reference Manual • August 2001
followed by
poweroff
.
poweron