Selection 2 enables you to change the test control flags (
CODE EXAMPLE 2-2
{0}Selection:2
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}Selection:
Note – If diag-switch = false, POST is disabled. If diag-switch = true and
diag-level = max, POST runs in max mode. If diag-switch = true and
diag-level = min, POST runs in min mode.
To run POST, power cycle the system.
2.2
Pre-POST Preparation
1. Connect a terminal to the LOM serial port on the Netra T4 server to view POST
progress and error messages. See Section G.1, "Connecting to the LOM Serial
Port" on page G-1.
Note – By default, the input and output device is the LOM serial port. To direct
POST output to ttya or ttyb, set both input-device and output-device to ttya
or ttyb:
2. Set the diag-switch? and diag-out-console configuration variables to true:
ok setver diag-switch? true
ok setver diag-out-console true
POST Test Control Flags Menu
0
Return
1
Run all Tests in this Menu
2
Change Test Control Flags
3
* Toggle Trace Flag - c
4
* Toggle Loop-a-test flag - l
5
* Toggle Loop-on-error flag - e
6
* Toggle Print-all-error flag
7
* Display current state of all flags
8
* Help on Test Flags
CODE EXAMPLE 2-2
- p
Chapter 2 Power-On Self Test
):
2-3