Storage Devices; Fc-Al Hard Disk Drive - Sun Microsystems Netra T4 AC100 Service And System Reference Manual

Hide thumbs Also See for Netra T4 AC100:
Table of Contents

Advertisement

8
C H A P T E R

Storage Devices

This chapter contains procedures for removing and fitting the Netra T4 system
storage devices.
The chapter contains the following sections:
Section 8.1, "FC-AL Hard Disk Drive" on page 8-1
Section 8.2, "Fiber Channel Backplane and Drive Bay" on page 8-6
Section 8.3, "Removable Media Module" on page 8-10
Caution – The plug at the end of the AC power cord is the primary means of
disconnection for the Netra T4 AC100 system.
8.1

FC-AL Hard Disk Drive

The following procedure is concerned with the physical removal and replacement of
a hard disk drive as
A non hot swap device
A hot swap device
From an operational point of view, whether a disk can be considered to be a hot
swap device and can be removed without shutting down Solaris depends on how
the disk drives are configured in the operating environment.
The disk is a hot swap device if:
The disk is not a root disk.
or if both of the following statements are true:
The disk is a root disk.
The disk is mirrored or RAID 5-protected.
8-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netra t4 dc100

Table of Contents