45) Installation of Power Unit

1.
Hoist power unit with rope as shown.
2.
Clean surface of power unit that contacts with the engine base,
and install dowel pin 1 and new gasket 2.
Install power unit 3, and tighten bolts 4 in two or three steps
3.
to specified torque.
Power Unit Installation Bolt :
30 N · m (22 lb · ft) [3.0 kgf · m]
Be careful not to catch wires and hoses and other
parts between power unit and engine base.
Attach drive shaft housing cover 5.
4.
5.
Install other parts by reversing the procedure described in
"Chapter 5 Removing Power Unit".

46) Removing Recoil Starter

Adjustment of Starter Lock Cable

1.
Shift gear into neutral (N).
Check that maximum diameter section of slide 1 is at
2.
neutral start mark 2.
3.
If not, adjust lower side of cable.
4.
Perform shift operation to check that recoil starter is locked
at other than neutral (N) position.
4st 9.9/15/20 2008
3
2
1
1
4
1
1 Slide
2 Neutral start mark
5
2
5-63