· Measurement condition Circuit tester to be
used : HIOKI3030
Measurement Range : 1kΩ
· Permissible Error of Resistance : ±20%
Note) 1 It is recommended to use "HIOKI HiTESTER MODEL 3030" for this measurement. Use of other instrument
model for the measurement can cause indication of abnormal value for normal condition, resulting in
inaccurate measurement.
2 Disconnect all connections to measure as an independent unit.
3 Any movement of pointer indicates "ON" or "conductive" state.
4 "CON" means that the pointer moves once and then returned to the value shown in ( ) because of
characteristic of capacitor.
5 The value in ( ) is the condition applied when "1kΩ" range is used. The measurement varies widely among types
of instrument, situations (such as inner power supply), or measurement ranges due to diodes used in the unit.

7. CD Unit Coupler

●Check wire harness for disconnection of lead wire and
defective connection.
●Terminals are arranged and numbered as shown.
●The following table shows names of terminals, their
numbers and lead wire colors.
No.
Name
1
Ignition (GND)
2
Ignition (+)
3
Exciter (H)
4
Exciter (L)
5
Tachometer
6
LED power
7
Vacant
8
Stop Watch
9
GND
10
Vacant
11
LED
12
Pulser (+)
13
Pulser (-)
14
Vacant
15
Oil Pressure Switch
16
Vacant
4st 9.9/15/20 2008
Lead Wire
Or
Orange
B
Black
B/R
Black/Red
L
Blue
W
White
W/R
White/Red
Br
Brown
B
Black
Lg
Yellowish Green
R/W
Red/White
B
Black
Br/W
Brown/White
14
10
6
12
16
8
15
11
7
13
9
5
2
4
3
1