9) Inspection of Stop Switch
1.
Check conduction of stop switch, and replace if not
conductive.
This test can be made without removing parts.
Switch Position
Remove lock a
Attach lock b
Press switch c
5. Starting System
1) Inspection of Fuse
Check electrical conductivity of fuse a. Replace if no
1.
conductivity.
Flat or small sized plate fuse (20A) is adopted.
2) Inspection of Starter Solenoid
1.
Connect tester lead wires to both terminals of starter
solenoid.
2.
Connector green (G) lead wire to battery positive terminal.
3.
Connector black (B) lead wire to battery negative terminal.
4.
Check electrical conductivity between terminals of starter
solenoid. Replace if no conductivity.
5.
Remove battery terminal from green (G) or black (B) lead
wire, and check there is no conductivity between starter
solenoid terminals. Replace if conductive.
4st 9.9/15/20 2008
Lead Wire Color
Brown (Br)
Black (B)
a
b
c
a
8
8-17