Power Unit
49) Installation of Recoil Starter
Reverse disassembly procedure to assemble by taking
care of the following matters.
●When setting starter spring into starter case, face starter
spring outer edge hook to the right and set it into peripheral
cut of starter case.
●Run starter rope through rope guide 1.
●When installing reel into starter case, set projection of reel
in the internal hook of starter spring.
●Apply cold resistance lithium grease to the following parts.
· Starter Spring
· Reel Center Hole
· Ratchet
· Starter Lock
· Friction Plate
●Apply "Three Bond" 1342 to starter shaft bolt, and tighten
the bold to specified torque.
Starter Shaft Bolt :
6 N · m (4 lb · ft) (0.6 kgf · m)
●When applying tension to starter spring, turn reel 4 to 5
times to direction to which the reel rotates when pulling out
starter rope (counterclockwise). When applying tension to
starter spring, turn reel 4 to 5 times to direction to which the
reel
rotates
(counterclockwise).
●Perform shift operation to check that recoil starter is locked
at other than neutral (N) position.
5-66
when
pulling
out
starter
1
1 Rope Guide
2 Friction Spring
3 Friction Plate
4 Starter Shaft Bolt
rope
2
4
1342
1342
1342
3
LIT
LIT
4st 9.9/15/20 2008
LIT
LIT
LIT
LIT