Signal Contact; Manual Setting - Hirschmann rsb20 Reference Manual

Web-based interface industrial ethernet switch
Hide thumbs Also See for rsb20:
Table of Contents

Advertisement

Diagnostics

7.6 Signal contact

The signal contacts are used for
controlling external devices by manually setting the signal contacts,
monitoring the functions of the device,
reporting the device state of the device.
7.6.1

Manual Setting

 Select the "Signal Contact 1" or "Signal Contact 2" card index (for devices
with two signal contacts).
 Select the "Manual Setting" mode in the "Signal Contact Mode" field. This
mode enables you to control this signal contact remotely.
 Select "Open" in the "Manual Setting" field to open the contact.
 Select "Closed" in the "Manual Setting" field to close the contact.
Application options:
Simulation of an error during SPS error monitoring.
Remote control of a device via SNMP, such as switching on a camera.
114
7.6 Signal contact
RM Web L2B
Release 5.3 05/2012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Octopus os20Octopus os24

Table of Contents