Hirschmann RS20 User Manual page 155

Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Synchronizing the system time in the
GPS
Reference
(Grandmaster Clock)
10.0.1.2
Boundary
Figure 50: Example of PTP synchronization
Device
PTP
Operation
Clock Mode
Preferred Master
SNTP
Operation
Server destination ad-
dress
Server VLAN ID
Client external server
address
Request interval
Accept broadcasts
Table 11: Settings for the example
Basic Configuration L2P
Release 4.2 07/08
Switch mit
RT-Modul
10.0.1.112
Clock
Switch ohne
RT-Modul
10.0.1.105
10.0.1.112
10.0.1.116
on
on
ptp-mode-
ptp-mode-
boundary-clock
boundary-clock
true
false
on
off
0.0.0.0
0.0.0.0
1
1
10.0.1.2
0.0.0.0
30
any
no
any
(see fig. 50)
8.3 Precision Time Protocol
Switch mit
RT-Modul
10.0.1.116
Ordinary Clock
Switch ohne
10.0.1.105
ptp-mode-
simple-ptp
false
off
0.0.0.0
1
0.0.0.0
any
any
RT-Modul
10.0.1.106
10.0.1.106
on
ptp-mode-
simple-ptp
false
off
0.0.0.0
1
0.0.0.0
any
any
155