Hirschmann RS20 User Manual page 157

Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Synchronizing the system time in the
Device
PTP
Operation
Clock Mode
Preferred Master
SNTP
Operation
Server destination address
Server VLAN ID
Send interval
Client external server address 149.218.112.0
Request interval
Accept broadcasts
Table 12: Settings for the example
In the example, the left device, as an SNTP client, gets the time from the
NTP server via SNTP. The device assigns clock stratum "2" to the time
received from an NTP server. Thus the left device becomes the reference
clock for the PTP synchronization. PTP is active for all three devices, thus
providing precise time synchronization between them. As the connectable
terminal devices in the example only support SNTP, all three devices act
as SNTP servers.
Basic Configuration L2P
Release 4.2 07/08
149.218.112.1
149.218.112.2
on
on
ptp-mode-
ptp-mode-
boundary-clock
boundary-clock
false
false
on
on
224.0.1.1
224.0.1.1
1
1
30
30
0.0.0.0
any
any
no
no
8.4 Interaction of PTP and SNTP
149.218.112.3
on
ptp-mode-
boundary-clock
false
on
224.0.1.1
1
30
0.0.0.0
any
no
157