Saving In A File On Url - Hirschmann RS20 User Manual

Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Loading/saving settings

3.2.2 Saving in a file on URL

The device allows you to save the current configuration data in a file in the
connected network.
Note: The configuration file includes all configuration data, including the
password. Therefore pay attention to the access rights on the tftp server.
Select the
Basics: Load/Save dialog.
In the "Save" frame, click "on URL (binary)" to receive a binary file,
or "on URL (script)" to receive an editable and readable script.
In the "URL" frame, enter the path under which you want the device
to save the configuration file.
The URL identifies the path to the tftp server on which the device saves
the configuration file. The URL is in the format tftp://IP address of the
tftp server/path name/file name (e.g. tftp://149.218.112.5/
switch/config.dat).
Click "Save configuration".
enable
copy nvram:startup-config
tftp://149.218.112.159/
switch/config.dat
copy nvram:script tftp://
10.0.1.159/switch/config.txt
60
Switch to the Priviledged EXEC mode.
The device saves the configuration data in a bina-
ry file on a tftp server in the connected network
The device saves the configuration data in a
script file on a tftp server in the connected net-
work
3.2 Saving settings
Basic Configuration L2P
Release 4.2 07/08