Operation diagnosis
The events which can be selected are:
Name
Meaning
Authentication The device has rejected an unauthorized access attempt (see the Access
for IP Addresses and Port Security dialog).
Cold Start
The device has been switched on.
Link Down
At one port of the device, the link to the device connected there has been
interrupted.
Link Up
At one port of the device, the link to a device connected there has been es-
tablished.
Spanning Tree The topology of the Rapid Spanning Tree has changed.
Chassis
Encompasses the following events: .
– The status of a supply voltage has changed (see the System dialog).
– Signaling relay: The status of the signal contact has changed. To take
this event into account, you activate "Trap for status change" in the Diag-
nostics:Signal Contact 1/2 dialog.
– An error has occurred in connection with the SNTP.
– A media module was added or removed.– The ACA AutoConfiguration
Adapter was added or removed.
– The temperature threshold was exceeded/not reached.
Redundancy
The redundancy status of the Hiper-Ring or the redundant ring/network
coupling has changed.
Port Security
At one port a data packet has been received from an unauthorized terminal
device (see the Port Security dialog).
Bridge
Although the BPDU Guard function is active at a port, a BPDU was re-
ceived (see Redundancy user manual, "Rapid Spanning Tree").
Table 14: Trap categories