3.2 Saving settings

In the "Save" frame, you have the option to
save the current configuration on the device
save the current configuration in binary form in a file under the specified
URL, or as an editable and readable script
save the current configuration in binary form or as an editable and read-
able script on the PC.

3.2.1 Saving locally (and on the ACA)

The device allows you to save the current configuration data in the local non-
volatile memory and in the ACA.
Select the
Basics: Load/Save dialog.
In the "Save" frame, click "on the Switch".
Click "Save configuration". The device saves the current configura-
tion data in the local non-volatile memory and, if an ACA is
connected, also in the ACA.
enable
copy system:running-config
nvram:startup-config
Basic Configuration L2P
Release 4.2 07/08
Switch to the Priviledged EXEC mode.
The device saves the current configuration data
in the local non-volatile memory and, if an ACA is
connected, also in the ACA