EPSON Stylus Photo R340/350

2.3.18 Removing the Lower Housing

Illustration
Lower Housing
Shaft
Stacker Shaft
Main Frame Insulator
Figure 2-65. Removing the Lower Housing
Disassembly and Assembly
Hooked Tabs
Compression Spring 5.1
Stacker Lock
Feet
Disassembly
Parts/Components must be removed to remove the Lower Housing.
Paper Support Assy., Left Housing, Right Housing,
Panel Board Assy. (Panel Board and LCD Module), Upper Housing,
Rear Housing, Main Board Assy., ASF Assy., Shaft Assy. Holder,
Printer Mechanism, Power Supply Assy., Waste Ink Pads, Stacker Assy.
Disassembly Procedure
1.
Release the two tabs ( ) that secure the Stacker Lock and remove the Stacker
Lock and the Compression Spring 5.1.
2.
Release the shaft of the Stacker Shaft with a flat-blade screwdriver and
remove the Stacker Shaft.
3.
Remove the three feet affixed on the bottom of the Lower Housing.
4.
Remove the two Main Frame Insulators from the Lower Housing.