Occurrence
Timing
Symptoms
CR Position
• Occurrence
The Carriage Unit hits against the right
Timing:
side of the Main Frame at power-on.
At power-on
• CR Position:
---
Troubleshooting
Table 1-6. Troubleshooting of Fatal Errors based on Observed Symptom (continued)
Failed Part
Head Cable
1. Check if the Head cable is correctly connected to the
2. Check if the Head Cable is damaged.
Troubleshooting
Check Point
connector on the CR Encoder Sensor Board and CN9 on
the Main Board.
CN9
Connector
Head Cable
Revision A
Remedies
1. Correctly connect the Head cable to the
connector on the CR Encoder Sensor Board
and CN9 on the Main Board.
2. Replace the Head Cable with a new one.