Can Tap Valve; T-Joint; R134A Refrigerant Recover And Recycling Machine - wsm M108S Workshop Manual

Table of Contents

Advertisement

M108S, WSM

(5) Can Tap Valve

(6) T-joint

(7) R134a Refrigerant Recover and Recycling Machine

The can tap valve that is used to charge the refrigerant into the
air conditioning system, should be used as follows :
1. Before putting the can tap valve on the refrigerant container, turn
the handle (1) counterclockwise till the valve needle is fully
retracted.
2. Turn the plate nut (disc) (4) counterclockwise till it reaches its
highest position, then screw down the can tap valve into the
sealed tap.
3. Turn the place nut clockwise fully, and fix the center charging
hose to the valve.
4. Tighten the place nut firmly by hand.
5. Turn the handle (1) clockwise, thus making a hole in the sealed
tap.
6. To charge the refrigerant into the system, turn the handle (1)
counterclockwise. To stop charging, turn it clockwise.
(1) Butterfly Handle
(2) Connection
T-joint (2) is used to increase efficiency of gas charging using two
refrigerant containers (4) at a time.
1. Install two refrigerant container service valves to T-joint (2) sides
and connect the charging hose (1) to it.
(1) Charging Hose (Green)
(2) T-joint
When there is necessity of discharging the refrigerant on
repairing the tractor, it should use recovery and recycling machine.
(Do not release the refrigerant into the atmosphere.)
IMPORTANT
• Use only R134a refrigerant recovery and recycling machine,
eliminate
mixing
refrigerant oils with R12 systems to prevent compressor
damage.
10-S12
(3) Needle
(4) Disc
(3) Can Tap Valve
(4) Refrigerant Container
R134a
equipment,
refrigerant
CABIN
W1015014
W1015169
and
W1015488
KiSC issued 05, 2012 A