Cleaning Air Cleaner Element
1. Remove the air cleaner cover (4) and primary element (2).
2. Clean the primary element if:
• When dry dust adheres to the element, blow compressed air from
the inside turning the element. Pressure of compressed air must
be under 205 kPa (2.1 kgf/cm
3. When replacing the air cleaner primary element (2), replace the
secondary element (1) as well :
Once a year or after every six times of cleaning, whichever
comes first.
IMPORTANT
• The air cleaner uses a dry element, never apply oil.
• Do not run the engine with filter element removed.
• Be sure to refit the dust cup with the arrow ↑ (on the rear of
cup) upright. If the dust cup is improperly fitted, evacuator
valve will not function and dust will adhere to the element.
• Do not touch the secondary element except in cases where
replacing is required.
Evacuator Valve
Open evacuator valve once a week under ordinary conditions or
daily when used in a dusty place to get rid of large particles of dust
and dirt.
(1) Secondary (Safety) Element
(2) Primary Element
Checking Fuel Line
1. Check to see that all lines and hose clamps are tight and not
damaged.
2. If hoses and clamps are found worn or damaged, replace or
repair them at once.
NOTE
• If the fuel line is removed, be sure to properly bleed the fuel
system.
Refer to "[14] OTHERS" in this section.
(1) Fuel Line
G-20
G GENERAL
2
, 30 psi).
(3) Evacuator Valve
(4) Cover
(2) Clamp Band
KiSC issued 05, 2012 A