Automatic Transmission
System Description (cont'd)
Hydraulic Flow (cont'd)
H Position: Driving in 1st gear
The PCM turns shift solenoid valve A OFF, but shift solenoid valves B and C remain ON. SH A pressure (SA) is applied
to the left side of shift valve A, then shift valve A is m o v e d t o the left side. This movement switches the port of line
pressure and CPC pressure on shift valve A. The 1st clutch pressure is changed to line pressure mode, and the 1st
clutch is engaged securely. The CPC A pressure (5E) stops at shift valve B.
NOTE:
• W h e n used, " l e f t " or " r i g h t " indicates direction o n the hydraulic circuit.
• Hydraulic circuit shows the '98-99 models; the '00-02 m o d e l s are similar.