14-92
If the JITC_MODE System Flag is set to YES and a valid TLS certificate is
installed, only secured connections are allowed:
If the JITC_MODE System Flag is set to YES and the Management Network
Service has not yet been configured to be secured, an Active Alarm is
created and a message is displayed stating that Secured Communications
Mode must be enabled.
If the JITC_MODE System Flag is set to YES and a valid TLS certificate has
not been installed, an Active Alarm is created and a message is displayed
stating that the system is in JITC Mode but Secured Communications Mode
is not enabled until the TLS certificate is installed.
13 On the workstation that was connected to the RMX in Step 11, start
the RMX Web Client application:
a
In the browser's address line, enter the Control Unit IP Address in
the format:
https://<Control Unit IP Address> (
or
http://<Control Unit IP Address> (
b
Press Enter.
The RMX Web Client – Terms of Usage screen is displayed. The banner
is enforced when the system is in JITC_MODE. The banner can be
customized.
Terms of Usage
Banner
Accept
Button
14 Click the Accept button to agree to the terms and conditions
displayed in the banner.