Monitoring Star Cascaded Conferences

To enable cascaded links to connect without a password:
1
In the RMX web client connected to MCU A (where the linked
conference is running), click Setup>System Configuration.
The System Flags dialog box opens.
2
Set the
ENABLE_CASCADED_LINK_TO_JOIN_WITHOUT_PASSWORD
YES.
3
Click OK.
For more information, see "System Configuration" on page 19-6.
Reset the MCU for flag changes to take effect.
>>
To monitor both conferences at the same time, two instances of the RMX
Web Clients must be opened (one for each MCU) by entering the IP
Address of each MCU. If both conferences are running on the same MCU,
only one RMX Web Client window is required.
When conferences are cascaded, the Participant list pane of each of the two
conferences will display a linked icon (
destination conference (Conference B) and a dial-out linked icon in the
linked conference (Conference A).
Polycom RMX 1500/2000/4000 Administrator's Guide
); a dial-in linked icon in the
flag to