Module Configuration

This section describes how to configure serial interfaces of HSSI-1 and WTE-
4S modules.

Configuring V.35

This section describes how to configure a serial interface, V.35. The other
serial interfaces such as RS-232, X.21, 449 and 530 are to be configured in the
similar way.
Configuring V.35 as a DCE
The following figure illustrates a connection of Ubigate iBG3026 configured
as a DCE.
Configuring Step
Step
1
2
3
4
5
6
7
8
9
© SAMSUNG Electronics Co., Ltd.
Command
Router# configure terminal
Router/configure# module serial
[slot /port]
Router/configure/module/serial([slot
/port])# mode V.35
Router/configure/module/serial([slot
/port])# V35
Router/configure/module/serial([slot
/port])/V35# mode dce
Router/configure/module/serial([slot
/port])/V35# clock_rate {56,000 to
52,000,000}
Router/configure/serial([slot/port])/V
35# clock_source {internal | line}
Router/configure/serial([slot/port])/V
35# crc {16 | 32}
Router/configure/serial([slot/port])/V
35# data_mode {normal | inverted}
Ubigate iBG3026 Configuration Guide/Ed.00
Purpose
Enters the terminal configuration
mode.
Selects a port to configure as a
serial module.
Selects a serial interface as a
V.35.
Enters the V.35 interface.
Selects V.35 mode as a DCE.
Selects a clock rate.
Selects a synchronization clock
source. As a DTE, the option,
'internal', is recommended.
Selects a CRC mode.
Selects a data mode.
41