OPER
indicates status changes while voice port or DS0 channel works. This appears
as 'up' in case that the voice port or DS0 channel is normally in service, and as
'down' while the voice port is out of service due to failure of voice card.
indicates as 'block' when blocked by an operator, or a channel is not available
when it signals.
IN STATUS
indicates status changes when analog voice port or DS0 channel handles a call.
At this time, call state is indicated differently according to signaling method in
each SIG-Type analog of voice port or DS0 channel.
'idle', 'ringing', 'off-hook', 'out_of_svc', 'busy', 'seized', 'answered' etc.
OUT STATUS
indicates status changes when analog voice port or DS0 channel handles a call.
At this time, call state is indicated differently according to signaling method in
each SIG-Type analog of voice port or DS0 channel.
'idle', 'ringing', 'off-hook', 'out_of_svc', 'busy', 'seized', 'answered' etc.
EC
indicates working of echo cancellation function set up in analog voice port or
DS0.
Logical Voice Port In Detail
displays the concrete setup values of the parameters used in a specific voice
port.
v239# show voice port 0/1/0:10
Voice Port protocol is DS0_SIG_R2_compelled
Description is not set
Noise Regeneration is enable
Echo Cancellation is enable
Echo Cancel Coverage is 48ms
Echo Non Linear Processing is disable
Input Gain is set to 0 dB
Output Attenuation is set to 0 dB
Playout-delay Mode is set to DjbMode_Static
Playout-delay Nominal is set to 40ms
Playout-delay Maximum is set to 200ms
Playout-delay Minimum is set to 20ms
Translation Rule for Calling is set to none