Samsung Ubigate iBG3026 Configuration Manual page 84

Hide thumbs Also See for Ubigate iBG3026:
Table of Contents

Advertisement

CHAPTER 6. Serial Interfaces
Configuring Example
The following figure illustrates a connection of Ubigate iBG3026 configured
as a HSSI DTE.
The following example shows the commands used to configure the connection
in the figure.
Router# configure terminal
Router/configure# module hssi 1/0
Router/configure/hssi (1/0)# mode dte
Router/configure/hssi (1/0)# clock_source line
Router/configure/hssi (1/0)# clock_rate 45000000
Router/configure/hssi (1/0)# crc 16
Router/configure/hssi (1/0)# data_mode normal
Router/configure/hssi (1/0)# name hssi1
Router/configure/hssi (1/0)# end
Router# show module configuration hssi 1/0
Configuring HSSI as a DCE
Configuring Step
Step
1
2
3
48
(HSSI DCE)
Network
FR Switdh
Command
Router# configure terminal
Router/configure# module hssi
[slot /port]
Router/configure/hssi([slot/port])#
mode dce
(HSSI DTE)
HSSI
iBG3026
Enters the terminal configuration
mode.
Selects a port to configure as a
HSSI module. [slot/port] denotes a
specified port in a specified slot.
Selects a HSSI mode as a DCE.
© SAMSUNG Electronics Co., Ltd.
Purpose