Samsung Ubigate iBG3026 Configuration Manual page 575

Hide thumbs Also See for Ubigate iBG3026:
Table of Contents

Advertisement

Delay-Dial signaling
Configure T1-CAS E & M signaling
Step
1
configure terminal
2
module t1 slot/sub-slot/port
3
cas-ds0-group ds0-group-no
4
exit
5
voice-port slot/sub-
slot/port:ds0-group-no
6
shutdown
7
timeslots timeslot-list
© SAMSUNG Electronics Co., Ltd.
Originating
M-wire
E-wire
1111
seizure
1111
0000
digits
digits
1111
Figure 31.12 Delay-dial method signaling sequence
Command
Ubigate iBG3026 Configuration Guide/Ed.00
Destination
M-wire
E-wire
Start dial
answer
Enter the global configuration mode.
Enter the module configuration mode.
Enter the ds0-group number to create in
this E1 trunk.
Exits the module configuration mode.
To set up the attribute values of created
ds0-group, starts with voice-port
configuration mode.
if ds0-group was created normally, there is
no error in this CLI command.
Shuts down the voice port to manipulate
'timeslots' and 'signal cas' command.
timeslots-Specifies the single time slot
number, single range of numbers, or
multiple ranges of numbers separated by
commas. For T1, allowable values are
from 1 to 24.
Examples are as follows:
-2, 3-5
-1, 7, 9
-1-12
Min 120 msec
Max 6 sec
Duration 200 msec
Min 70 msec
Max 10 sec
Min 200 msec
Purpose
533

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents