IANet:Loopback Test Failed
Explanation: A failure was detected during the Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check the Ethernet cable for damage and ensure correct cable type and attachment.
2. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
3. Rerun the test.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.

DSA LSI hard drive test results

The following messages can result when you run the LSI hard drive test.
407-000-000
LSIESG:DiskDefaultDiagnostic Test Passed
Explanation: The test passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
407-800-000
LSIESG:DiskDefaultDiagnostic Test Aborted
Explanation: The test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
407-900-000
LSIESG:DiskDefaultDiagnostic Test Failed
Explanation: The hard drive self-test detected a failure.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify whether the firmware is at the latest level.
4. Rerun the test.
5. If the problem remains, contact your IBM technical-support representative.