406-904-000 • 407-000-000
406-904-000
IANet:Loopback Test Failed
Explanation: A failure was detected during the Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check the Ethernet cable for damage and ensure correct cable type and attachment.
2. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
3. Rerun the test.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v

DSA LSI hard drive test results

The following messages are generated when you run the LSI hard drive test.
407-000-000
LSIESG:DiskDefaultDiagnostic Test Passed
Explanation: The test passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v