806f0207-2584xxxx
[ProcessorElementName] has Failed with FRB1/BIST condition. (All CPUs)
Explanation: This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST
condition.
May also be shown as 806f02072584xxxx or 0x806f02072584xxxx
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0044
SNMP Trap ID: 40
Automatically notify Support: Yes
User response:
1.
Make sure that the latest levels of firmware and device drivers are installed for all adapters and standard
devices, such as Ethernet, SCSI, and SAS. Important: Some cluster solutions require specific code levels or
coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is
supported for the cluster solution before you update the code.
2.
Update the firmware (UEFI and IMM) to the latest level (Updating the firmware).
3.
Run the DSA program.
4.
Reseat the adapter.
5.
Replace the adapter.
6.
(Trained technician only) Replace microprocessor n.
(Trained technician only) Replace the system board. (n = microprocessor number) One of the CPUs :
7.
806f020d-0400xxxx
Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 0)
Explanation: This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0400xxxx or 0x806f020d0400xxxx
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk drive b. Cable from the system board to the backplane.
3.
Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard
disk drive. b. Cable from the system board to the backplane. c. Hard disk drive backplane. (n = hard disk drive
number)