806f050c-200dxxxx
Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 13)
Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit
has been Reached.
May also be shown as 806f050c200dxxxx or 0x806f050c200dxxxx
Severity: Warning
Alert Category: Warning - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0144
SNMP Trap ID: 43
Automatically notify Support: Yes
User response:
1.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
2.
Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different
memory channel or microprocessor.
3.
If the error still occurs on the same DIMM, replace the affected DIMM.
4.
(Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the
connector contains any foreign material or is damaged, replace the system board.
5.
(Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any
damaged pins. If a damage is found, replace the system board.
6.
(Trained technician only) Replace the affected microprocessor.
806f050c-200exxxx
Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 14)
Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit
has been Reached.
May also be shown as 806f050c200exxxx or 0x806f050c200exxxx
Severity: Warning
Alert Category: Warning - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0144
SNMP Trap ID: 43
Automatically notify Support: Yes
User response:
1.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
2.
Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different
memory channel or microprocessor.
3.
If the error still occurs on the same DIMM, replace the affected DIMM.
4.
(Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the
connector contains any foreign material or is damaged, replace the system board.
5.
(Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any
damaged pins. If a damage is found, replace the system board.
6.
(Trained technician only) Replace the affected microprocessor.
806f050c-200dxxxx • 806f050c-200exxxx