IBM System x3550 M4 Installation And Service Manual page 441

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

806f000d-0407xxxx
The Drive [StorageVolumeElementName] has been added. (Drive 7)
Explanation: This message is for the use case when an implementation has detected a Drive has been Added.
May also be shown as 806f000d0407xxxx or 0x806f000d0407xxxx
Severity: Info
Alert Category: Critical - Hard Disk drive
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0162
SNMP Trap ID: 5
Automatically notify Support: No
User response: No action; information only.
806f000f-220101xx
The System [ComputerSystemElementName] has detected no memory in the system. (ABR
Status)
Explanation: This message is for the use case when an implementation has detected that memory was detected in
the system.
May also be shown as 806f000f220101xx or 0x806f000f220101xx
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0794
SNMP Trap ID: 41
Automatically notify Support: No
User response:
Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
1.
2.
Recover the server firmware from the backup page: a. Restart the server. b. At the prompt, press F3 to recover
the firmware.
3.
Update the server firmware on the primary page. Important: Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is
supported for the cluster solution before you update the code.
Remove components one at a time, restarting the server each time, to see if the problem goes away.
4.
5.
If the problem remains, (trained technician only) replace the system board.
Firmware Error : Sys Boot Status :
806f000d-0407xxxx • 806f000f-220101xx
Appendix A. Integrated management module II (IMM2) error messages
423