IBM System x3550 M4 Installation And Service Manual page 791

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

166-818-001
IMM I2C Test Aborted
Explanation: Cannot execute duplicated request.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
166-819-001
IMM I2C Test Aborted
Explanation: Command response could not be provided. SDR Repository in?update mode.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
166-820-001
IMM I2C Test Aborted
Explanation: Command response could not be provided. Device in firmware update mode.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
166-818-001 • 166-820-001