IBM System x3550 M4 Installation And Service Manual page 719

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

516-801-000
ELXUCNA: NIC PHY LoopBackTest Aborted
Explanation: Loopback testing at the physical layer was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
516-802-000
ELXUCNA: ELXUCNA: NIC LED(Beacon)Test Aborted
Explanation: Verification of status LEDs was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
516-900-000
ELXUCNA: NIC MAC LoopBackTest Failed
Explanation: A failure was detected during the loopback test at the MAC layer.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
516-901-000
ELXUCNA: NIC PHY LoopBackTest Failed
Explanation: A failure was detected during the loopback test at the physical layer.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
516-801-000 • 516-901-000
Appendix C. DSA diagnostic test results
701