IBM System x3550 M4 Installation And Service Manual page 415

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

80010901-2d01xxxx
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted. (PCH
Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109012d01xxxx or 0x800109012d01xxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Reduce the ambient temperature.
2.
Ensure the air baffle is installed correctly.
3.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010902-0701xxxx
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
Explanation: This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109020701xxxx or 0x800109020701xxxx
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 1
Automatically notify Support: Yes
User response: If the specified sensor is Planar 3.3V or Planar 5V, (Trained technician only) replace the system
board. If the specified sensor is Planar 12V, complete the following steps until the problem is solved:
Check power supply n LED.
1.
2.
Remove the failing power supply.
3.
(Trained technician only) Replace the system board. (n = power supply number)
80010901-2d01xxxx • 80010902-0701xxxx
Appendix A. Integrated management module II (IMM2) error messages