IBM System x3550 M4 Installation And Service Manual page 411

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

80010901-1002xxxx
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted. (PCI
Riser 2 Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109011002xxxx or 0x800109011002xxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Reduce the ambient temperature.
2.
Ensure the air baffle is installed correctly.
3.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010901-1401xxxx
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
(CPU1 VR Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109011401xxxx or 0x800109011401xxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
Reduce the ambient temperature.
1.
2.
Ensure the air baffle is installed correctly.
3.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010901-1002xxxx • 80010901-1401xxxx