806f050d-0405xxxx • 806f050d-0406xxxx
806f050d-0405xxxx
Array [ComputerSystemElementName] is in critical condition. (Drive 5)
Explanation: This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0405xxxx or 0x806f050d0405xxxx
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
Check backplane cable connection.
4.
Replace the RAID adapter.
5.
6.
Replace the hard disk drive that is indicated by a lit status LED.
806f050d-0406xxxx
Array [ComputerSystemElementName] is in critical condition. (Drive 6)
Explanation: This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0406xxxx or 0x806f050d0406xxxx
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
Replace the SAS cable.
3.
Check backplane cable connection.
4.
Replace the RAID adapter.
5.
6.
Replace the hard disk drive that is indicated by a lit status LED.
504
IBM System x3550 M4 Type 7914: Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents