IBM System x3550 M4 Installation And Service Manual page 409

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

80010701-2c01xxxx
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
(Mezz Card Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107012c01xxxx or 0x800107012c01xxxx
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Reduce the temperature.
2.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010701-2d01xxxx
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
(PCH Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107012d01xxxx or 0x800107012d01xxxx
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
Reduce the temperature.
1.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
2.
exiting the server.
80010701-2c01xxxx • 80010701-2d01xxxx
Appendix A. Integrated management module II (IMM2) error messages
391

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents