Dsa Intel Network Test Results - IBM System x3550 M4 Installation And Service Manual

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

217-800-000 • 406-000-000
217-800-000
HDD Test Aborted
Explanation: HDD Test Aborted. The test was canceled.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify that Hard drive supports self test and self test logging.
4. If the problem remains, contact your technical-support representative.
217-900-000
HDD Test Failed
Explanation: HDD Test Failed. The hard drive self-test detected a failure.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify the firmware is at the latest level.
4. Rerun the test.
5. If the problem remains, contact your technical-support representative.

DSA Intel network test results

The following messages can result when you run the Intel network test.
406-000-000
IANet:Registers Test Passed
Explanation: The test passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
704