IBM System x3550 M4 Installation And Service Manual page 552

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

806f090c-2018xxxx • 806f0a07-0301xxxx
806f090c-2018xxxx
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 24)
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2018xxxx or 0x806f090c2018xxxx
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f0a07-0301xxxx
[ProcessorElementName] is operating in a Degraded State. (CPU 1)
Explanation: This message is for the use case when an implementation has detected a Processor is running in the
Degraded state.
May also be shown as 806f0a070301xxxx or 0x806f0a070301xxxx
Severity: Warning
Alert Category: Warning - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0038
SNMP Trap ID: 42
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffles are in place and correctly installed, and that the server cover is installed and completely
closed.
2.
Check the ambient temperature. You must be operating within the specifications.
3.
Make sure that the heat sink for microprocessor n is installed correctly.
4.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
534
IBM System x3550 M4 Type 7914: Installation and Service Guide