IBM System x3550 M4 Installation And Service Manual page 433

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b010c-2581xxxx
Redundancy Lost for [RedundancySetElementName] has asserted. (Backup Memory)
Explanation: This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010c2581xxxx or 0x800b010c2581xxxx
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 41
Automatically notify Support: No
User response:
1.
Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup utility.
800b0309-1301xxxx
Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for
[RedundancySetElementName] has asserted. (Power Resource)
Explanation: This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded
or Fully Redundant to Non-redundant:Sufficient.
May also be shown as 800b03091301xxxx or 0x800b03091301xxxx
Severity: Warning
Alert Category: Warning - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0806
SNMP Trap ID: 10
Automatically notify Support: No
User response:
Non-redundant sufficient: Power load will be handled by remaining power supply, though the system may
1.
throttle to avoid a power supply over-current condition.
Replace the power supply with higher rated power.
2.
800b010c-2581xxxx • 800b0309-1301xxxx
Appendix A. Integrated management module II (IMM2) error messages
415

Hide quick links:

Advertisement

Table of Contents
loading