IBM System x3550 M4 Installation And Service Manual page 430

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

80070608-0a02xxxx • 80070614-2201xxxx
80070608-0a02xxxx
Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to
non-recoverable.
May also be shown as 800706080a02xxxx or 0x800706080a02xxxx
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response: If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is
solved:
1.
Use the IBM Power Configurator utility to determine current system power consumption. For more information
and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
2.
Follow actions in "Power Problems and Solving Power Problems".
If the specified sensor is PS n 12V OV Fault, complete the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Remove the failing power supply.
3.
(Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete the following steps until the problem is solved:
Check power supply n LED.
1.
2.
Remove the failing power supply.
3.
Follow actions in "Power Problems and Solving Power Problems".
4.
(Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12Vaux Fault, complete the following steps until the problem is solved:
Check power supply n LED.
1.
2.
Replace power supply n. (n = power supply number)
80070614-2201xxxx
Sensor [SensorElementName] has transitioned to non-recoverable. (TPM Phy Pres Set)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to
non-recoverable.
May also be shown as 800706142201xxxx or 0x800706142201xxxx
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Update the server firmware (see Recovering the server firmware).
2.
If the problem persists, (trained technician only) replace the system board (see Removing the system board and
Installing the system board).
412
IBM System x3550 M4 Type 7914: Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents