IBM System x3550 M4 Installation And Service Manual page 682

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

816f0a13-0302xxxx
816f0a13-0302xxxx
System [ComputerSystemElementName] has recovered from a Fatal Bus Error. (CPU 2 PECI)
Explanation: This message is for the use case when an implementation has detected that a system has recovered
from a Bus Fatal Error.
May also be shown as 816f0a130302xxxx or 0x816f0a130302xxxx
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0245
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat sink and Replacing
a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU with the same error indication, replace the system board.
3.
(Trained technician only) Replace the system board (see Removing the system board and Replacing the system
board). (n = microprocessor number)
664
IBM System x3550 M4 Type 7914: Installation and Service Guide