806f0a0c-200cxxxx
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 12)
Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c200cxxxx or 0x806f0a0c200cxxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in
place and correctly installed, and that the server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the specifications.
3.
If a fan has failed, complete the action for a fan failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-200dxxxx
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 13)
Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c200dxxxx or 0x806f0a0c200dxxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in
place and correctly installed, and that the server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the specifications.
3.
If a fan has failed, complete the action for a fan failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-200cxxxx • 806f0a0c-200dxxxx
Appendix A. Integrated management module II (IMM2) error messages
541